Название | Assessment of two nearby interfering strip footings of different embedment depths in saturated cohesive soils // Magazine of Civil Engineering. – 2024. – Т. 17, № 5. — С. 12906 |
---|---|
Авторы | Ayasrah M. A. ; Fattah M. Y. |
Выходные сведения | 2024 |
Коллекция | Общая коллекция |
Тематика | Строительство ; Основания и фундаменты ; ribbon foundations ; connected soils ; saturated cohesive soils ; nearby foundations ; foundation depth ; load-bearing capacity (construction) ; ленточные фундаменты ; связные грунты ; насыщенные связные грунты ; близлежащие фундаменты ; глубина заделки фундаментов ; несущая способность (строительство) |
УДК | 624.1 |
ББК | 38.58 |
Тип документа | Статья, доклад |
Тип файла | |
Язык | Английский |
DOI | 10.34910/MCE.129.6 |
Права доступа | Свободный доступ из сети Интернет (чтение, печать, копирование) |
Дополнительно | Новинка |
Ключ записи | RU\SPSTU\edoc\75304 |
Дата создания записи | 18.02.2025 |
There are instances where foundations are closely spaced, such as around railroad sleepers and foundations close to property lines. In such circumstances, the stress isobars of the separate footings may interact and combine to generate an overlapping stress isobar that affects a wider zone of the foundation soil and alters the individual foundations behavior, which would be different from that of the isolated footings. As a result, an examination of such issues should be conducted by taking into account all the variables that realistically affect the interference behavior of such closely spaced footings. A numerical study is carried out using the finite element program (Midas GTS-NX), and the behavior of closely placed strip footings of different depths embedded in the saturated cohesive soils is investigated under the influence of different factors such as the spacing between footings, the depth of footings, soil undrained shear strength, and the groundwater table. The evaluated ultimate bearing capacity (UBC) and settlements are represented in terms of non-dimensional efficiency factors for UBC: xi[L]/xi[R] (Left/Right). It was concluded that when the spacing between footings is increased from S/B = 1 to 2, there would be an increase in the UBC of both footings when D[fr]/D[fl] increases, then the bearing capacity decreases when S/B is increased to 4. For footings of different embedment depths, when the ground water table is deep (at 4 m depth), the values of UBC ratio hi[R] increase with S/B while hiL decreases. This is because of various embedment between the two adjacent footings. In all cases, when the ground water table is at the ground surface, lower values in xi[L] are at Cu = 60 kPa, while the higher values in xi[R] are found at this strength.
- Assessment of two nearby interfering strip footings of different embedment depths in saturated cohesive soils
- 1. Introduction
- 2. Methods
- 2.1. Finite Element Method
- 2.2. Construction Stages
- 2.3. Definition of Bearing Capacity Ratio (ξ)
- 3. Results and Discussions
- 3.1. Footings of Different Depths
- 4. Conclusions