Таблица | Карточка | RUSMARC | |
Разрешенные действия: Прочитать Загрузить (0,6 Мб) Группа: Анонимные пользователи Сеть: Интернет |
Аннотация
The paper is devoted to the possibility of construction of the quantum frequency standard based on two quantum magnetometers system. One of the magnetometers is based on self-oscillation spin generator, another is M[z]-type magnetometer based on end microwave resonance. The laser pumping of {87}Rb atoms placed into anti-relaxation coated cell is provided. The experimental results on the magnetometers frequency difference fluctuations measurements and Allan deviation are presented. The role of the radio-optical resonance frequency light shift different components is noted for the choosing the quantum magnetometers optimal operation mode. The effect of the light shift compensation is demonstrated.
Права на использование объекта хранения
Статистика использования
Количество обращений: 543
За последние 30 дней: 14 Подробная статистика |