Title: Диагностические функции силового пьезопреобразователя в устройствах для HIFU терапии: выпускная квалификационная работа магистра: направление 16.04.01 «Техническая физика» ; образовательная программа 16.04.01_08 «Физика медицинских технологий»
Creators: Шмыр Даниил Сергеевич
Scientific adviser: Лукин Александр Яковлевич
Organization: Санкт-Петербургский политехнический университет Петра Великого. Институт электроники и телекоммуникаций
Imprint: Санкт-Петербург, 2022
Collection: Выпускные квалификационные работы; Общая коллекция
Subjects: Преобразователи силовые; высокоинтенсивный фокусированный ультразвук; мониторинг; абляция; деформация; эхо-сигнал; импеданс; согласование импедансов; high-intensity focused ultrasound; monitoring; ablation; deformation; echo line; impedance; impedance matching
UDC: 621.314.1
Document type: Master graduation qualification work
File type: PDF
Language: Russian
Level of education: Master
Speciality code (FGOS): 16.04.01
Speciality group (FGOS): 160000 - Физико-технические науки и технологии
DOI: 10.18720/SPBPU/3/2023/vr/vr23-370
Rights: Доступ по паролю из сети Интернет (чтение, печать, копирование)
Record key: ru\spstu\vkr\20645

Allowed Actions:

Action 'Read' will be available if you login or access site from another network Action 'Download' will be available if you login or access site from another network

Group: Anonymous

Network: Internet

Annotation

Тема выпускной квалификационной работы: «Диагностические функции силового пьезопреобразователя в устройствах для HIFU терапии». Данная работа посвящена созданию экспериментальной установки, позволяющей использовать силовой пьезопреобразователь не только для терапии, но и для диагностики исследуемого биологического объекта. Экспериментальная установка способна осуществлять термическую абляцию, формировать короткий зондирующий сигнал, а также регистрировать эхо-сигнал. Оценка степени воздействия HIFU – излучения заключалась в анализе эхогенности и величины деформации объекта посредством акустической пальпации. С помощью силового излучателя удалось зарегистрировать изменения в биологическом объекте, произошедшие в результате термической абляции. Помимо этого, тем же излучателем возможно контролировать температуру, а также проверять наличие или отсутствие рабочей жидкости. Контроль осуществляется путём измерения модуля и фазы импеданса излучателя. Данная работа направлена на совершенствование комплексов HIFU-терапии, разрабатываемых Лабораторией ультразвуковых технологий.

The subject of the graduate qualification work is “Diagnostic functions of a power piezoelectric transducer in devices for HIFU therapy”. The given work is devoted to the creation of an experimental facility which allow to use of a power piezoelectric transducer for therapy and diagnostics of a biological object. The system is able to perform thermal ablation, form a short probe signal, and also register an echo signal. Estimate of the degree of exposure to HIFU radiation consisted in the analysis of echogenicity and deformation of the object by acoustic radiation force impulse. As a result, it was possible to register changes in the biological object after thermal ablation. In addition, it is possible to control the temperature and check the presence of the working fluid with a power transducer. In addition, it is possible to control the temperature and check the presence of the working fluid with a power transducer. Control is carried out by measuring the modulus and phase of the impedance of the transducer. The work is aimed at improving the HIFU-therapy complexes developed by the Laboratories of ultrasonic technologies.

Document access rights

Network User group Action
ILC SPbPU Local Network All Read Print Download
Internet Authorized users SPbPU Read Print Download
-> Internet Anonymous

Table of Contents

  • Содержание
  • Список аббревиатур и сокращений
  • Введение
  • Глава 1. Двухрежимные ультразвуковые преобразователи
  • 1.1. Одноэлементные преобразователи
  • 1.2. Многоэлементные преобразователи
  • Глава 2. Экспериментальная установка
  • 2.1. Описание установки
    • 2.1.1. Излучатель
    • 2.1.2. ПК
    • 2.1.3. Генератор ультразвукового излучения
    • 2.1.4. Регистрация сигналов
  • 2.2. Согласующая цепь.
  • 2.3. Подбор мощности
  • 2.4. Оценка интенсивности излучателя.
  • 2.5. Подбор зондирующего сигнала
  • 2.6. Приём эхо сигнала.
  • Глава 3. Мониторинг результатов HIFU – абляции
  • 3.1. Организация эксперимента
    • 3.1.1. HIFU воздействие
    • 3.1.2. Диагностика и подбор времени продавливания
  • 3.2. Исследование эхогенности объекта
  • 3.3. Исследование деформации объекта
    • 3.3.1. Сравнение смещения
    • 3.3.2. Результаты HIFU – воздействия
  • Глава 4. Мониторинг состояния излучателя.
  • 4.1. Зависимость модуля импеданса излучателя от температуры
  • 4.2. Зависимость фазы импеданса излучателя от температуры
  • 4.3. Зависимость импеданса от наличия или отсутствия воды
  • 4.4. Проверка наличия акустического контакта
  • 4.5. Анализ результатов измерений
  • Заключение
  • Список литературы