Details

Title: Deflection of a cladding panel of fully tempered glass in curtain wall system // Magazine of Civil Engineering. – 2021. – № 4 (104). — С. 10403
Creators: Gerasimova E. N.; Galyamichev A. V.; Schwind G.; Schneider J.
Imprint: 2021
Collection: Общая коллекция
Subjects: Строительство; Строительные конструкции; facing panels; tempered glass; curtain walls; facades; evenly distributed load; mechanical behavior of facades; aluminum frames; облицовочные панели; закаленное стекло; навесные стены; фасады; равномерно распределенная нагрузка; механическое поведение фасадов; алюминиевые каркасы
UDC: 624.01
LBC: 38.5
Document type: Article, report
File type: PDF
Language: English
DOI: 10.34910/MCE.104.3
Rights: Свободный доступ из сети Интернет (чтение, печать, копирование)
Record key: RU\SPSTU\edoc\67142

Allowed Actions: Read Download (1.5 Mb)

Group: Anonymous

Network: Internet

Annotation

The article presents a study on the mechanical behavior of facade cladding panel consisting of aluminum frame and fully tempered sheet glass under the action of uniformly distributed load. The study involved tests of full-size samples of two structural solutions of the cladding panel in a curtain wall system for two different geometrical configurations of the panel. Experimental data showed a high similarity with the results of a static calculation in the zone of linear elastic deformation. Therefore, the use of SJ Mepla finite element software package for the calculation of described structures was verified. The influence of the boundary conditions on determination of deflections in numerical model as well as the character of seal deformation was described. The criteria of the loss of bearing capacity of a system was defined. Empirical formulas for calculating the panel deflection for specific geometrical configurations of a panel were proposed.

Document access rights

Network User group Action
ILC SPbPU Local Network All Read Print Download
-> Internet All Read Print Download

Table of Contents

  • Deflection of a cladding panel of fully tempered glass in curtain wall system
    • 1. Introduction
    • 2. Methods
      • 2.1. Experimental approach
      • 2.2. Numerical approach
    • 3. Results and Discussion
    • 4. Conclusions

Usage statistics

stat Access count: 140
Last 30 days: 15