Детальная информация

Название Effect of irregularity on seismic design parameters of RC-infilled structures // Magazine of Civil Engineering. – 2021. – № 8 (108). — С. 10807
Авторы Shendkar M.; Beiraghi H.; Mandal S.
Выходные сведения 2021
Коллекция Общая коллекция
Тематика Строительство; Строительные конструкции; reinforced concrete structures; seismic parameters; calculated seismic parameters; brickwork walls; structural irregularities; seismic engineering; железобетонные конструкции; сейсмические параметры; расчетные сейсмические параметры; кирпичная кладка стен; неровности конструкций; сейсмическое проектирование
УДК 624.01
ББК 38.5
Тип документа Статья, доклад
Тип файла PDF
Язык Английский
DOI 10.34910/MCE.108.7
Права доступа Свободный доступ из сети Интернет (чтение, печать, копирование)
Ключ записи RU\SPSTU\edoc\67994
Дата создания записи 24.03.2022

Разрешенные действия

Прочитать Загрузить (1,2 Мб)

Группа Анонимные пользователи
Сеть Интернет

A four-storey reinforced concrete (RC) building is seismically evaluated with the incorporation of different irregularities. Three model systems have been considered, i. e., model I: (RC-infilled regular frame in X and Y direction), model II: (RC-infilled plan irregular frame in X and Y direction), and model III: (RC infilled vertical + plan irregular frame in X and Y direction). Adaptive pushover analyses have been carried out to evaluate the seismic performance of the structure by using seismostruct software incorporating inelastic material behaviour for concrete, steel, and infill walls. Infill walls have been modelled as “double strut nonlinear cyclic models”. The most up-to-date seismic design includes the nonlinearity in the structure through a response reduction factor (R). The ductility reduction factor and overstrength factor are the main components of the response reduction factor. These seismic design parameters were computed from the adaptive pushover analysis, and finally, the response reduction factor has been calculated for all models and compared with the value recommended by IS 1893 part-1 (2016). The result shows that the evaluated R-factors are higher than the value recommended by the BIS code. However, it is observed that R-values are higher than the corresponding values recommended in the BIS code when the irregularity present in the structures.

Место доступа Группа пользователей Действие
Локальная сеть ИБК СПбПУ Все
Прочитать Печать Загрузить
Интернет Все

Количество обращений: 231 
За последние 30 дней: 4

Подробная статистика