Details

Title Effect of irregularity on seismic design parameters of RC-infilled structures // Magazine of Civil Engineering. – 2021. – № 8 (108). — С. 10807
Creators Shendkar M. ; Beiraghi H. ; Mandal S.
Imprint 2021
Collection Общая коллекция
Subjects Строительство ; Строительные конструкции ; reinforced concrete structures ; seismic parameters ; calculated seismic parameters ; brickwork walls ; structural irregularities ; seismic engineering ; железобетонные конструкции ; сейсмические параметры ; расчетные сейсмические параметры ; кирпичная кладка стен ; неровности конструкций ; сейсмическое проектирование
UDC 624.01
LBC 38.5
Document type Article, report
File type PDF
Language English
DOI 10.34910/MCE.108.7
Rights Свободный доступ из сети Интернет (чтение, печать, копирование)
Record key RU\SPSTU\edoc\67994
Record create date 3/24/2022

Allowed Actions

Read Download (1.2 Mb)

Group Anonymous
Network Internet

A four-storey reinforced concrete (RC) building is seismically evaluated with the incorporation of different irregularities. Three model systems have been considered, i. e., model I: (RC-infilled regular frame in X and Y direction), model II: (RC-infilled plan irregular frame in X and Y direction), and model III: (RC infilled vertical + plan irregular frame in X and Y direction). Adaptive pushover analyses have been carried out to evaluate the seismic performance of the structure by using seismostruct software incorporating inelastic material behaviour for concrete, steel, and infill walls. Infill walls have been modelled as “double strut nonlinear cyclic models”. The most up-to-date seismic design includes the nonlinearity in the structure through a response reduction factor (R). The ductility reduction factor and overstrength factor are the main components of the response reduction factor. These seismic design parameters were computed from the adaptive pushover analysis, and finally, the response reduction factor has been calculated for all models and compared with the value recommended by IS 1893 part-1 (2016). The result shows that the evaluated R-factors are higher than the value recommended by the BIS code. However, it is observed that R-values are higher than the corresponding values recommended in the BIS code when the irregularity present in the structures.

Network User group Action
ILC SPbPU Local Network All
Read Print Download
Internet All

Access count: 299 
Last 30 days: 14

Detailed usage statistics