Details

Title: Effect of irregularity on seismic design parameters of RC-infilled structures // Magazine of Civil Engineering. – 2021. – № 8 (108). — С. 10807
Creators: Shendkar M.; Beiraghi H.; Mandal S.
Imprint: 2021
Collection: Общая коллекция
Subjects: Строительство; Строительные конструкции; reinforced concrete structures; seismic parameters; calculated seismic parameters; brickwork walls; structural irregularities; seismic engineering; железобетонные конструкции; сейсмические параметры; расчетные сейсмические параметры; кирпичная кладка стен; неровности конструкций; сейсмическое проектирование
UDC: 624.01
LBC: 38.5
Document type: Article, report
File type: PDF
Language: English
DOI: 10.34910/MCE.108.7
Rights: Свободный доступ из сети Интернет (чтение, печать, копирование)
Record key: RU\SPSTU\edoc\67994

Allowed Actions: Read Download (1.2 Mb)

Group: Anonymous

Network: Internet

Annotation

A four-storey reinforced concrete (RC) building is seismically evaluated with the incorporation of different irregularities. Three model systems have been considered, i. e., model I: (RC-infilled regular frame in X and Y direction), model II: (RC-infilled plan irregular frame in X and Y direction), and model III: (RC infilled vertical + plan irregular frame in X and Y direction). Adaptive pushover analyses have been carried out to evaluate the seismic performance of the structure by using seismostruct software incorporating inelastic material behaviour for concrete, steel, and infill walls. Infill walls have been modelled as “double strut nonlinear cyclic models”. The most up-to-date seismic design includes the nonlinearity in the structure through a response reduction factor (R). The ductility reduction factor and overstrength factor are the main components of the response reduction factor. These seismic design parameters were computed from the adaptive pushover analysis, and finally, the response reduction factor has been calculated for all models and compared with the value recommended by IS 1893 part-1 (2016). The result shows that the evaluated R-factors are higher than the value recommended by the BIS code. However, it is observed that R-values are higher than the corresponding values recommended in the BIS code when the irregularity present in the structures.

Document access rights

Network User group Action
ILC SPbPU Local Network All Read Print Download
-> Internet All Read Print Download

Usage statistics

stat Access count: 192
Last 30 days: 16
Detailed usage statistics