Details

Title: Исследование режимов и динамической устойчивости электроэнергетической системы 220/110 кВ: выпускная квалификационная работа бакалавра: направление 13.03.02 «Электроэнергетика и электротехника» ; образовательная программа 13.03.02_01 «Электроэнергетические системы и сети»
Creators: Шагалиева Алина Ильдаровна
Scientific adviser: Рындина Ирина Евгеньевна
Other creators: Першиков Георгий Анатольевич
Organization: Санкт-Петербургский политехнический университет Петра Великого. Институт энергетики
Imprint: Санкт-Петербург, 2020
Collection: Выпускные квалификационные работы; Общая коллекция
Subjects: электроэнергетическая система; электроэнергетическое оборудование; установившийся режим работы; несимметричное короткое замыкание; переходные процессы; динамическая устойчивость; electric power system; electric power apparatus; steady state operation; asymmetric short circuit; transient processes (phanomena); dynamical stability
Document type: Bachelor graduation qualification work
File type: PDF
Language: Russian
Level of education: Bachelor
Speciality code (FGOS): 13.03.02
Speciality group (FGOS): 130000 - Электро- и теплоэнергетика
Links: Отзыв руководителя; Отчет о проверке на объем и корректность внешних заимствований
DOI: 10.18720/SPBPU/3/2020/vr/vr20-3057
Rights: Доступ по паролю из сети Интернет (чтение, печать, копирование)
Record key: ru\spstu\vkr\6955

Allowed Actions:

Action 'Read' will be available if you login or access site from another network Action 'Download' will be available if you login or access site from another network

Group: Anonymous

Network: Internet

Annotation

В данной работе было проведено исследование электроэнергетической системы 220/110 кВ. В первую очередь, был произведен выбор и проверка электроэнергетического оборудования, такого как: генератор, трансформатор и автотрансформатор, линии электропередачи. Проверка трансформаторов и автотрансформаторов осуществлялась по максимальной расчетной нагрузке. При определении сечения ЛЭП проходила проверка по длительно допустимому току. Во второй главе был произведен расчет нормального (установившегося) режима работы электроэнергетической системы. Первоначально была составлена схема замещения и её параметры (активные и реактивные сопротивления, индуктивные проводимости ЛЭП ). Расчет заданной энергосистемы был реализован дважды: вручную и с помощью ПО «RastrWin». Вручную мы рассчитывали падения напряжения, потери мощности. С помощью «RastrWin» был выполнен расчет максимальных нагрузок и минимальных нагрузок. Результатом второй главы являлось сравнение двух расчетом. Суть третьей главы заключалась в расчете токов и напряжений несимметричного (однофазного) короткого замыкания. Прежде всего было произведено приведение параметров энергосистемы к базисным условиям, затем была составлена эквивалентная комплексная схема замещения для прямой и обратной последовательности. Итогом третьей главы стало определение токов и напряжений в месте КЗ и построение векторных диаграмм. Окончанием работы являлась проверка на устойчивость данной энергосистемы к коротким замыканиям (динамическая устойчивость). В ходе данной проверки было определено время, при котором энергосистема теряет устойчивость, а также были реализованы меры по увеличению данного времени (повышение динамической устойчивости).

In this work, research was conducted of the electric power system 220/110 kV. First of all, selection and verification of electric power equipment was made, such as: generator, transformer and autotransformer, power lines. Transformers and autotransformers checked at the maximum rated load. The check was carried out for a continuous current when determining the cross section of the power transmission line. In the second chapter, the normal (steady-state) mode of operation of the electric power system was calculated. Initially, an equivalent circuit and its parameters (active and reactive resistances, inductive conductivity of power lines) were drawn up. The calculation of a given power system was implemented twice: manually and using the RastrWin software. Manually we calculated voltage drops, power losses. Using "RastrWin" the calculation of maximum loads and minimum loads. The essence of the third chapter was to calculate the currents and voltages of an asymmetric (single-phase) short circuit. First of all, the power system parameters were brought to basic conditions, then an equivalent complex equivalent circuit was compiled for the forward and reverse sequence. The result of the third chapter was the determination of currents and voltages in the place of the short circuit and the construction of vector diagrams. The end of the work was a check for the stability of this power system to short circuits (dynamic stability). During this check, the time was determined at which the power system loses stability, and measures were taken to increase this time (increase dynamic stability).

Document access rights

Network User group Action
ILC SPbPU Local Network All Read Print Download
External organizations N2 All Read
External organizations N1 All
Internet Authorized users SPbPU Read Print Download
Internet Authorized users (not from SPbPU, N2) Read
Internet Authorized users (not from SPbPU, N1)
-> Internet Anonymous

Table of Contents

  • по направлению 13.03.02 Электроэнергетика и электротехника
    • ЗАДАНИЕ
      • студент Шагалиева Алина Ильдаровна, группа 3231302/60101
    • Исходные данные для выполнения выпускной квалификационной работы
      • студент Шагалиева Алина Ильдаровна, группа 3231302/60101
  • РЕФЕРАТ
  • ВВЕДЕНИЕ
    • ГЛАВА 1. ВЫБОР ЭЛЕМЕНТОВ ЭЛЕКТРОЭНЕРГИТИЧЕСКОЙ СИСТЕМЫ
      • 1.1. Выбор и проверка трансформаторов и автотрансформаторов
      • 1.2. Выбор и проверка сечений линий электропередачи
    • ГЛАВА 2. РАСЧЕТ УСТАНОВИВШЕГОСЯ РЕЖИМА РАБОТЫ ЭЛЕКТРОЭНЕРГЕТИЧЕСКОЙ СИСТЕМЫ
      • 2.1. Составление схемы замещения
      • 2.2. Расчет режима энергосистемы
      • 2.3. Расчет установившегося режима работы сети с помощью программного обеспечения
    • ГЛАВА 3. ВЫЧИСЛЕНИЕ ТОКОВ И НАПРЯЖЕНИЙ НЕСИММЕТРИЧНОГО КОРОТКОГО ЗАМЫКАНИЯ
      • 3.1. Допущения, принимаемые при вычислении коротких замыканий.
      • 3.2. Приведение параметров схемы к относительным единицам.
      • 3.3.Составление и преобразование комплексной схемы замещения
      • 3.4.Определение токов и напряжений в месте короткого замыкания
    • ГЛАВА 4. РАСЧЕТ ДИНАМИЧЕСКОЙ УСТОЙЧИВОСТИ
      • 4.1. Расчет параметров элементов схемы замещения
      • 4.2. Короткое замыкание
      • 4.3. Мероприятия по повышению динамической устойчивости электроэнергетических систем
  • ЗАКЛЮЧЕНИЕ
  • СПИСОК ИСПОЛЬЗУЕМЫХ ИСТОЧНИКОВ