Details

Title: Исследование методов диагностики для КЛ из СПЭ на 35 кВ: выпускная квалификационная работа бакалавра: направление 13.03.02 «Электроэнергетика и электротехника» ; образовательная программа 13.03.02_07 «Высоковольтные электроэнергетика и электротехника»
Creators: Дружинин Евгений Васильевич
Scientific adviser: Дудкин Сергей Михайлович
Organization: Санкт-Петербургский политехнический университет Петра Великого. Институт энергетики
Imprint: Санкт-Петербург, 2023
Collection: Выпускные квалификационные работы; Общая коллекция
Subjects: кабель; сшитый полиэтилен; дефекты кабеля; дефекты муфт; методы диагностики; надёжность; вероятность безотказной работы; средний класс напряжения; cable; cross-linked polyethylene; cable defects; coupling defects; diagnostic methods; reliability; probability of trouble-free operation; average voltage class
Document type: Bachelor graduation qualification work
File type: PDF
Language: Russian
Level of education: Bachelor
Speciality code (FGOS): 13.03.02
Speciality group (FGOS): 130000 - Электро- и теплоэнергетика
DOI: 10.18720/SPBPU/3/2023/vr/vr23-2067
Rights: Доступ по паролю из сети Интернет (чтение, печать)
Record key: ru\spstu\vkr\24461

Allowed Actions:

Action 'Read' will be available if you login or access site from another network

Group: Anonymous

Network: Internet

Annotation

Данная работа посвящена исследованию дефектов и методов диагностики кабелей и муфт для кабельной линии с изоляцией из сшитого полиэтилена на 35 кВ и разработка мероприятий для увеличения надёжности кабельной линии. Задачи, которые решались в ходе исследования: 1) Изучение особенностей дефектов кабельной линии с изоляцией из сшитого полиэтилена. 2) Разбор методов диагностики для выявления дефектов кабельной линии с изоляцией из сшитого полиэтилена. 3) Расчёт надёжности кабельной линии и влияния мероприятий по уменьшению дефектов кабелей, муфт и кабельной линии на надёжность кабельной линии. В результате изучены причины выхода из строя кабельной линии, повреждения кабеля происходят чаще всего из-за земляных работ в местах прокладки кабельной линии, повреждения муфты происходят чаще всего из-за некачественного монтажа. На основе проведённых расчётов оказалось, что проведение комплексных мероприятия по уменьшению монтажных дефектов муфт и эксплуатационных дефектов кабелей позитивно сказывается на надёжности кабельной линии, производственные дефекты влияют минимально.

This work is devoted to the study of defects and diagnostic methods of cables and couplings for a cable line with 35 kV cross-linked polyethylene insulation and the development of measures to increase the reliability of the cable line. Tasks that were solved during the study: 1) Study of the features of defects in a cable line with insulation made of cross-linked polyethylene. 2) Analysis of diagnostic methods for detecting defects in a cable line with insulation made of cross-linked polyethylene. 3) Calculation of the reliability of the cable line and the impact of measures to reduce defects in cables, couplings and cable lines on the reliability of the cable line. As a result, the reasons for the failure of the cable line have been studied, cable damage occurs most often due to excavation work in places where the cable line is laid, coupling damage occurs most often due to poor-quality installation. Based on the calculations carried out, it turned out that carrying out complex measures to reduce mounting defects of couplings and operational defects of cables has a positive effect on the reliability of the cable line, production defects have a minimal effect.

Document access rights

Network User group Action
ILC SPbPU Local Network All Read Print
Internet Authorized users SPbPU Read Print
-> Internet Anonymous

Table of Contents

  • ОБОЗНАЧЕНИЯ И СОКРАЩЕНИЯ
  • ВВЕДЕНИЕ
  • 1 КАБЕЛИ С ИЗОЛЯЦИЕЙ ИЗ СПЭ
  • 1.1 Конструкция кабеля с изоляцией из СПЭ на 35 кВ
  • 1.2 Дефекты кабеля
  • 1.2.1 Производственные дефекты в изоляции
  • 1.2.2 Производственные дефекты в полупроводящем экране
  • 1.2.3 Дефекты оболочки кабеля при монтаже
  • 1.2.4 Дефекты изоляции кабеля при эксплуатации
  • 1.3 Диагностика кабелей
  • 1.3.1 Методы диагностики на производстве
  • 1.3.2 Методы диагностики оболочки при эксплуатации
  • 1.3.3 Методы диагностики изоляции кабеля при эксплуатации
  • 1.3.4 Методы диагностики для жил при эксплуатации
  • 1.3.5 Оборудование для диагностики ЧР в изоляции кабеля
  • 1.3.6 Вывод по диагностике кабеля
    • 2 МУФТЫ В КЛ С ИЗОЛЯЦИЕЙ ИЗ СПЭ
  • 2.1 Назначение муфт
  • 2.1.1 Классификация муфт для КЛ из СПЭ
  • 2.2 Разделка кабеля перед установкой муфты
  • 2.2.1 Соединение жил кабеля перед монтажом соединительной муфты
  • 2.2.2 Выравнивание линий напряженности электрического поля
  • 2.3 Конструкция муфт и их дефекты
  • 2.3.1 Основные элементы муфт холодной усадки
  • 2.3.2 Общие дефекты обоих видов муфт
  • 2.3.3 Дефекты муфт холодной усадки
  • 2.3.4 Основные элементы конструкции термоусадочных муфт
  • 2.3.5 Дефекты термоусадочных муфт
  • 2.4 Методы диагностики муфты
  • 2.4.1 Приемо-сдаточные испытания для изоляции арматуры
  • 2.4.2 Испытание на образцах арматуры
  • 2.4.3 Типовые испытания арматуры
  • 2.4.4 Электрические испытания после прокладки
  • 2.4.5 Методы диагностики муфт в эксплуатации
  • 2.4.6 Основные сложности при работе с муфтами
    • 3 НАДЕЖНОСТЬ КАБЕЛЬНОЙ ЛИНИИ
  • 3.1 Основные понятия о надёжности и статистика
  • 3.2 Расчёт надёжности кабельной линии
  • 3.3 Проведение мероприятий и их влияние на надёжность
  • 3.3.1 Влияние эффективности мероприятий на надёжность КЛ
    • ЗАКЛЮЧЕНИЕ
    • СПИСОК ИСПОЛЬЗОВАННЫХ ИСТОЧНИКОВ

Usage statistics