Details

Title: Разработка элегазового дугогасительного устройства 500 кВ, 50 кА: выпускная квалификационная работа бакалавра: направление 13.03.02 «Электроэнергетика и электротехника» ; образовательная программа 13.03.02_06 «Электрические и электронные аппараты»
Creators: Титаренко Михаил Николаевич
Scientific adviser: Аверьянова Светлана Андреевна
Organization: Санкт-Петербургский политехнический университет Петра Великого. Институт энергетики
Imprint: Санкт-Петербург, 2023
Collection: Выпускные квалификационные работы; Общая коллекция
Subjects: высоковольтный выключатель; автогенерация; численное моделирование параметров дугогасящего газа; отключающая способность; high-voltage switch; auto-generation; numerical simulation of arc-extinguishing gas parameters; breaking capacity
Document type: Bachelor graduation qualification work
File type: PDF
Language: Russian
Level of education: Bachelor
Speciality code (FGOS): 13.03.02
Speciality group (FGOS): 130000 - Электро- и теплоэнергетика
DOI: 10.18720/SPBPU/3/2023/vr/vr23-2151
Rights: Доступ по паролю из сети Интернет (чтение, печать, копирование)
Record key: ru\spstu\vkr\24545

Allowed Actions:

Action 'Read' will be available if you login or access site from another network Action 'Download' will be available if you login or access site from another network

Group: Anonymous

Network: Internet

Annotation

В работе исследованы параметры дугогасящего газа, влияющие на отключающую способность дугогасительного устройства, предложена модернизация дугогасительного устройства 500кВ, 50кА и проведена оценка увеличения ее отключающей способности. Задачи, решённые в работе: 1. Проведен анализ взаимодействия выключателя с сетью. 2. Изучены математические модели оценки отключающей способности различных типов дугогасительных устройств. 3. Предложена модернизация проточной части дугогасительного устройства. 4. Проведен анализ отключающей способности модернизированного автогенерационного дугогасительного устройства в сравнении с автокомпрессионным аналогом. Рассмотрены существующие в настоящее время высоковольтные выключатели 500 кВ. Выполнен анализ наиболее сложных режимов отключения выключателей 500кВ, 50кА. Изучение современных подходов к увеличению давления в нуле тока позволило сформулировать направление модернизации дугогасительного устройства. Изучение современных математических моделей для исследования динамики параметров дугогасящего газа позволило оценить изменение отключающей способности в модифицированном дугогасительном устройстве. Показаны границы применимости предложенной модификации.

In this paper, the parameters of the arc-extinguishing gas affecting the shut-off capacity of the arc-extinguishing device are investigated, the modernization of the 500kV, 50kA arc-extinguishing device is proposed and an assessment of the increase in its shut-off capacity is carried out. Tasks solved in the work: 1. The analysis of the interaction of the switch with the network is carried out. 2. Mathematical models for evaluating the breaking capacity of various types of arc extinguishing devices have been studied. 3. The modernization of the flow part of the arc extinguishing device is proposed. 4. The analysis of the shut-off capacity of the upgraded arc extinguishing device with heating volume arc extinguishing device in comparison with the auto-puffer analog is carried out. The currently existing 500 kV high-voltage circuit breakers are considered. The analysis of the most complex shutdown modes of 500kV, 50kA switches has been performed. The study of modern approaches to increasing the pressure at zero current allowed us to formulate the direction of modernization of the arc extinguishing device. The study of modern mathematical models for studying the dynamics of the parameters of the arc-extinguishing gas allowed us to estimate the change in the breaking capacity in the modified arc-extinguishing device. The limits of applicability of the proposed modification are shown.

Document access rights

Network User group Action
ILC SPbPU Local Network All Read Print Download
Internet Authorized users SPbPU Read Print Download
-> Internet Anonymous

Table of Contents

  • Введение.
  • Глава 1. Элегазовые высоковольтные выключатели.
    • 1.1. Обзор современных элегазовых выключателей 500кВ.
    • 1.2. Дугогасительное устройство автогенерирующего типа.
    • 1.3. Факторы, влияющие на отключающую способность выключателя в тепловой фазе пробоя.
    • 1.4. Влияние абляции сопла на повышение давления в дугогасительном устройстве.
      • 1.4.1. Экспериментальные данные.
      • 1.4.2. Анализ экспериментальных данных.
    • 1.5. Постановка задачи.
    • Выводы
  • Глава 2. Взаимодействие высоковольтных выключателей 500 кВ, 50 кА с сетью.
    • 2.1. Расчет ПВН при НКЗ (90%,30%)
    • 2.2. Анализ ПВН при КЗ 100% (при I=Iно и I=0,1Iно)
    • 2.3. Оценка влияния шунтирующей емкости на отключающую способность
    • Выводы
  • Глава 3. Математическая модель анализа отключающей способности автогенерирующего дугогасительного устройства.
    • 3.1. Моделирование динамики дугогасящего потока.
    • 3.2. Моделирование динамики дугогасительного газа в пакете Comsol.
    • Выводы
  • Глава 4. Расчет динамических характеристик автогенерирующего дугогасительного устройства (SF6) 500 кВ, 50кА.
    • 4.1. Расчет геометрии дугогасительного устройства.
    • 4.2. Анализ полей параметров элегаза в различных типах дугогасительных устройств.
    • 4.3 Анализ отключающей способности дугогасительного устройства 500 кВ, 50 кА.
    • Выводы
  • Заключение.
  • Список источников

Usage statistics

stat Access count: 14
Last 30 days: 0
Detailed usage statistics