Details

Title: The influence of reinforcing joints on the fire resistance of reinforced concrete structures // Magazine of Civil Engineering. – 2020. – № 8 (100). — С. 10004
Creators: Rybakov V. A.; Zhuvak O. V.; Hoffmann A.; Sergeeva F. A.; Verigo P. A.
Imprint: 2020
Collection: Общая коллекция
Subjects: Строительство; Строительные конструкции; reinforced concrete structures; fire resistance of building structures; einforcing joints; coupling joints; rod reinforcement; fire protection; reinforced concrete; железобетонные конструкции; огнестойкость строительных конструкций; армирующие соединения; муфтовые соединения; стержневые арматуры; огнезащита; железобетоны
UDC: 624.01
LBC: 38.5
Document type: Article, report
File type: PDF
Language: English
DOI: 10.18720/MCE.100.4
Rights: Свободный доступ из сети Интернет (чтение, печать, копирование)
Record key: RU\SPSTU\edoc\66143

Allowed Actions: Read Download (1.2 Mb)

Group: Anonymous

Network: Internet

Annotation

This article analyzes the behavior of reinforcing joints when exposed to a fire load. The scientific work presents the results of an experiment on the fire resistance of reinforcing samples with coupling and welded joints. Experimental studies of cold and hot tensile samples were carried out. A test of loaded, heated and cooled rods was also performed, simulating the real effect of a fire on a loaded structure. During all three experiments, the values of the deformation and strength characteristics of the mechanical and welded joints of the bar reinforcement were compared. The experiment was verified in the Abaqus software package for the coupling connection in flexible reinforced concrete structures. Coefficients were derived that take into account the decrease in the strength of a reinforcing specimen with a sleeve connection depending on the heating temperature in the stressed state. Based on the data obtained using the studies, it can be concluded that the coupling and welded joints of the reinforcing bars give additional rigidity to the samples, without compromising the strength characteristics of the reinforcing bar. In the course of the experiments, the coupling and welded joints proved to be approximately the same, it should be noted that from the point of view of application efficiency, coupling joints have significant technological advantages compared to the welded joint.

Document access rights

Network User group Action
ILC SPbPU Local Network All Read Print Download
-> Internet All Read Print Download

Table of Contents

  • The influence of reinforcing joints on the fire resistance of reinforced concrete structures
    • 1. Introduction
    • 2. Methods
      • 2.1. "Cold" experiment No 1: tensile test to rupture of "cold" samples, at room temperature 20 C
      • 2.2. " Hot "experiment No 2: tensile testing prior to rupture of" hot " samples preheated to 500 C
      • 2.3. Experiment No 3: Test of loaded, heated and cooled steel bars simulating the real impact of fire on the loaded structure
    • 3. Results and Discussion
      • 3.1. Experiment No 1. Cold samples
      • 3.2. Experiment No 2. Hot samples
      • 3.3. Experiment No 3. Testing of heated and cooled samples under load
      • 3.4. Discussion
    • 4. Conclusion
    • 5. Acknowledgments

Usage statistics

stat Access count: 173
Last 30 days: 9
Detailed usage statistics